Home Energy Bills: kWh, MJ, BTU and Therms Compared
How to compare electricity, gas and heating figures across kilowatt-hours, megajoules, BTU and therms, with worked examples for heat pumps and boilers.
Open a pile of household energy paperwork and you may meet four different units for what is essentially the same thing. Your electricity bill uses kilowatt-hours. Your gas bill might use kilowatt-hours, therms, megajoules or gigajoules, depending on where you live. A heater's label may list BTU per hour. Food packaging uses kilocalories. All of them measure energy or its rate, and all of them convert cleanly, once you know the anchors. This guide gives you those anchors, plus the worked examples that make comparisons honest.
The anchors to remember
The joule is the SI unit of energy: one watt for one second. Everything else is a multiple or a convenient chunk.
| Unit | Equivalent |
|---|---|
| 1 kilowatt-hour (kWh) | 3.6 megajoules (exactly) |
| 1 kWh | about 3,412 BTU |
| 1 BTU | about 1,055 joules |
| 1 therm | 100,000 BTU, about 29.3 kWh, about 105.5 MJ |
| 1 gigajoule (GJ) | about 277.8 kWh |
| 1 kilocalorie | 4.184 kilojoules |
The exact relation between the kilowatt-hour and the megajoule is worth memorising, because it is not an approximation: one kilowatt is 1,000 joules per second, one hour is 3,600 seconds, and so one kWh is 3,600,000 joules. To go from MJ to kWh, divide by 3.6. To go from kWh to MJ, multiply by 3.6.
Power versus energy, again
A large source of confusion is that kilowatts, BTU per hour and horsepower are rates, while kilowatt-hours, megajoules, BTU and therms are totals. A 3 kW heater is a rate. Run it for two hours and you have used 6 kWh. In the same way, a window air conditioner rated at 12,000 BTU/h can remove that much heat each hour; it is not a quantity of energy by itself. The old "ton" of cooling is just 12,000 BTU/h, about 3.5 kW.
Turning a gas meter into kWh
Gas meters count volume, not energy, but gas bills increasingly charge by energy content. In the United Kingdom, for example, the conversion works like this:
kWh = volume (m³) × volume correction × calorific value (MJ/m³) ÷ 3.6
The calorific value is printed on your bill and changes slightly with the gas supply; it usually sits in the high 30s of MJ per cubic metre. The volume correction is a small factor, around 1.02, that adjusts for temperature and pressure. As an illustration, 100 m³ of gas with a calorific value of 39.5 MJ/m³ and a correction of 1.02264 gives 100 × 1.02264 × 39.5 ÷ 3.6 = about 1,122 kWh.
Imperial meters read in hundreds of cubic feet. One hundred cubic feet is about 2.83 cubic metres, so convert to metric first and then apply the formula. In the United States, bills usually state a "therm factor" for converting the metered volume to therms. A cubic foot of natural gas carries a little over 1,000 BTU, so roughly one therm per hundred cubic feet, but use the factor on your own bill.
Comparing electricity and gas fairly
Price per unit of energy is the right starting point, but it is not the whole story, because heat sources convert energy at different efficiencies.
Suppose gas costs 8 cents per kWh and electricity costs 25 cents per kWh. Those are hypothetical prices, not forecasts. A gas boiler that is 90% efficient turns each purchased kWh of gas into 0.9 kWh of heat, so the cost per heat kWh is 8 ÷ 0.9 = about 8.9 cents. Electric resistance heating is close to 100% efficient, so heat costs 25 cents per kWh — nearly three times as much.
A heat pump changes the picture. Its coefficient of performance (COP) states how many units of heat it moves for each unit of electricity. At a COP of 3, heat costs 25 ÷ 3 = about 8.3 cents per kWh, similar to the boiler in this example. The break-even rule is simple: a heat pump costs less to run than a gas boiler whenever the electricity-to-gas price ratio is below COP ÷ boiler efficiency, which here is 3 ÷ 0.9 = 3.3. Seasonal COP varies with outdoor temperature, so use a realistic annual figure rather than a brochure peak.
Reading appliance labels
Heating and cooling equipment mixes systems. A US air conditioner might show cooling capacity in BTU/h and an energy efficiency ratio, EER, which is BTU/h of cooling per watt of input. Divide EER by 3.412 to get a COP. An EER of 10.2 is a COP of about 3.0. Gas appliances in the US may list input in BTU/h, while European boilers list output in kW. When comparing models, put both on the same footing: convert BTU/h to kW by multiplying by 0.2931.
Example: a furnace with a 80,000 BTU/h input rating at 95% efficiency delivers 76,000 BTU/h of heat, or about 22.3 kW. A 5 kW electric heater would need more than four units to match it for output at full load.
Everyday sense-checks
- A kettle rated at 2 kW running three minutes uses 0.1 kWh, or 0.36 MJ.
- A person eating 2,000 kcal takes in about 8.4 MJ, or 2.3 kWh. That is the energy of a modest evening of electric heating.
- One kWh equals about 860 kilocalories, which is why food energy looks so large next to household electricity.
Common mistakes
- Comparing a price per therm with a price per kWh without converting. Divide the therm price by 29.3 to get cost per kWh.
- Ignoring efficiency. Fuel energy is not the same as delivered heat.
- Mixing MJ and kWh when reading a bill that gives both. The factor is 3.6, not 3 or 4.
- Confusing BTU with BTU/h. The first is a quantity; the second is a rate.
The energy converter includes kilowatt-hours, joules, BTU, therms and calories, and the power converter covers kW and BTU/h.
Frequently asked questions
Why do some countries bill gas in megajoules and others in kWh?
It is partly historical practice. Some Australian and Canadian gas bills use megajoules or gigajoules, while the United Kingdom and much of Europe use kWh. Both describe the same energy, with a fixed factor of 3.6 between them.
Is a therm bigger than a kWh?
Yes, a therm is about 29 times larger. A therm of gas contains roughly as much energy as 29 kWh of electricity, although the cost per unit differs.
What does COP mean on a heat pump?
It is the ratio of heat delivered to electricity consumed. A COP of 3 means three units of heat for each unit of electricity, because the machine moves heat rather than creating it.
Why do bills show a calorific value?
Gas composition varies slightly, so the energy per cubic metre does too. The calorific value converts metered volume into the energy you are charged for.