The 2019 SI Redefinition: Ampere, Kelvin and Mole
How the ampere, kelvin and mole were redefined on 20 May 2019 using fixed constants, why the old definitions fell short, and what changed for everyday users.
When people talk about the 2019 changes to the International System of Units, the kilogram gets most of the attention. It was the dramatic one, because it retired a physical object. But the same revision, effective on 20 May 2019, also rewrote the definitions of three other base units: the ampere, the kelvin and the mole. This article looks at those three, what was wrong with their old definitions, and why the new ones are better.
The principle behind the revision
The 2019 revision applied a single idea to all seven base units. Instead of defining a unit by a recipe or an object, scientists fix the numerical value of a constant of nature and let the units follow. The metre had already been handled this way in 1983, through the speed of light, and the second had been tied to a caesium transition since 1967. The 2019 revision extended the approach to the rest.
Four constants were fixed exactly: the Planck constant, the elementary charge, the Boltzmann constant and the Avogadro constant. Together with the caesium frequency, the speed of light and a luminous-efficacy value for the candela, they define all seven base units. The result is that no SI unit now depends on an artefact, a particular material or a specific experiment.
The ampere: from wires to charge
The old ampere was defined through a thought experiment. Two long, thin, parallel wires in a vacuum, one metre apart, each carrying one ampere, would attract each other with a specific force per metre of length. The definition was elegant on paper, but nobody builds infinitely long wires, and the definition depended on the kilogram through the unit of force. Practical electrical standards were instead realised using quantum effects, which gave very reproducible results that were then converted, awkwardly, back to the old definition.
The new ampere is defined by fixing the elementary charge, the electric charge of a single proton, at exactly 1.602176634 × 10-19 coulombs. One ampere is then a flow of a particular number of elementary charges per second. The definition now matches how laboratories actually measure current, by counting charge through quantum devices, and it no longer needs the kilogram.
The kelvin: from one substance to a fixed energy scale
The old kelvin was defined as 1/273.16 of the thermodynamic temperature of the triple point of water, the unique condition at which ice, liquid and vapour coexist. That made one particular substance the reference for all temperature measurement. It also made the quality of the water matter: the isotopic mix of hydrogen and oxygen in the sample changes the triple-point temperature by a measurable amount, and metrologists had to specify a standard water composition.
The new kelvin fixes the Boltzmann constant at exactly 1.380649 × 10-23 joules per kelvin. This constant links temperature to the energy of molecular motion, so the definition ties temperature directly to energy. Water’s triple point is no longer a definition; it is a measured value, close to 273.16 K, with a small uncertainty. The temperature of 273.16 K for the triple point has now become a result, not an input.
The practical benefit appears at the extremes. Thermometry near absolute zero or at very high temperatures was awkward when everything had to be scaled from the water triple point. A definition based on a fixed constant lets laboratories realise the kelvin directly, at whatever temperature suits their equipment, such as with acoustic gas thermometers or noise thermometers.
The mole: from a mass to a count
The old mole was defined as the amount of substance containing as many elementary entities as there are atoms in 0.012 kilograms of carbon-12. That tied the mole to the kilogram, and it made the number of entities a measured quantity, known with a small uncertainty. Chemists had used the Avogadro number for over a century, but it was never exact.
The new mole fixes the Avogadro constant at exactly 6.02214076 × 1023 per mole. A mole is simply that many entities, whether atoms, molecules, ions or electrons. The mole is now a count, and its link to the kilogram is severed.
One subtle consequence is that the molar mass of carbon-12 is no longer exactly 12 grams per mole. It remains extremely close to that value, with a difference far below anything a chemistry laboratory could detect, but it is now a measured quantity with a small uncertainty rather than a definition.
The candela and the second: reworded, not recalculated
The candela and the second were also restated in the new style, though their underlying values did not change. The second is still defined from the caesium-133 hyperfine transition frequency of 9,192,631,770 hertz. The candela is defined by fixing the luminous efficacy of a specific green light at 540 terahertz to be 683 lumens per watt. The wording was rearranged so that all seven definitions follow the same pattern, a fixed constant with an exact value, and so that none of them refers to another base unit in a roundabout manner.
Did anything change for ordinary users?
No. The values of the fixed constants were chosen from the best measurements available before the revision, so that every unit stayed the same size to within the uncertainties of those measurements. A kitchen thermometer, a multimeter and a laboratory balance all read what they read before. The revision was planned and tested for years, with the international community agreeing to wait until independent experiments agreed on the constants to the required precision.
The effect is on the top of the traceability chain. National laboratories can now realise the units from first principles, using quantum devices, rather than relying on a comparison with an artefact or a prescribed substance. Over the long term, as instruments improve, the units can be realised with progressively smaller uncertainty without ever redefining them again.
A quick reference
| Unit | Fixed constant | Replaces |
|---|---|---|
| Ampere | Elementary charge, e | Force between parallel wires |
| Kelvin | Boltzmann constant, k | Triple point of water |
| Mole | Avogadro constant, NA | Atoms in 12 g of carbon-12 |
| Kilogram | Planck constant, h | The Paris prototype |
Common misunderstandings
- “Water no longer freezes at 0 °C.” It essentially still does; the distinction is that the figure is now measured, not defined.
- “A mole is a mass.” It is a number of entities. Molar mass is a separate quantity linking the two.
- “Everyone had to recalibrate.” The changes were designed to be invisible in everyday work.
Frequently asked questions
When did the new definitions take effect?
On 20 May 2019, which is World Metrology Day, the anniversary of the 1875 Metre Convention.
Which SI units are base units?
The metre, kilogram, second, ampere, kelvin, mole and candela. All other SI units are derived from these.
Why fix constants instead of improving the old definitions?
A fixed constant cannot drift, cannot be damaged, and can be realised anywhere. The old definitions depended on objects, substances or idealised experiments.
Is the Avogadro number exactly 6.022 × 1023?
The exact value is 6.02214076 × 1023. Shortened versions are fine for rough work but are not the definition.
Will the units be redefined again?
The second is the likeliest candidate, because optical clocks now outperform the caesium standard. The other units should not need to change.
For related conversions, see our temperature converter and electric current converter.